Gasoline heater
A gasoline heater is a small gasoline-fueled space-heater. Fixed versions were originally used mainly for supplemental heat for passenger compartments of automobiles and aircraft, with the latter still in production. Portable versions were also made.
Gasoline heaters were commercially available on automobiles starting in the 1930s with continued use until the 1960s, when they were almost entirely replaced with heaters that blow air past a small radiator warmed by hot engine coolant.
Operation
Gasoline is brought to the heater from the vehicle's fuel system. A fan blows air into a combustion chamber, where a glow plug or similar ignition device lights the gasoline/air mixture. Ducting around this contains a second fan, which blows air warmed by contact with the combustion chamber into the interior of the vehicle.
Electricity is required to heat the ignition source, with systems designed to be compatible with 6-volt, 12-volt, and 24-volt automotive and aircraft electrical systems.
Most gasoline heaters produce between 5,000 and 50,000 BTU per hour. A built-in safety switch prevents fuel from flowing unless the fan is working.
Safety
Gasoline heaters require an intake source of fresh air, and exhaust combusted gasses. Due to the toxicity of the latter - carbon monoxide in particular - it is crucial to prevent spent gasses from entering a vehicle's interior.
Other combustion byproducts include soot, sulfur dioxide, carbon dioxide, and some carbon monoxide.
Manufacturers
South Wind heaters
The South Wind Heater was invented by Canadian Harry J. McCollum,[1] who demonstrated his invention to the Stewart-Warner company in 1934.
Production at the Chicago firm began a short time later,[2] with more than 3 million units installed in automobiles, aircraft, and military vehicles by 1948.[1] These included 1940s Fords through early 1970s Volkswagens, and its Model M978 used in 1950s and 1960s military vehicles.
Others
Other manufacturers over the years have included Janitrol.[3] One current manufacturer of gasoline and diesel fueled heaters is the Espar corporation, of Ontario, Canada, a wholly owned subsidiary of the German company J. Eberspächer, the world's largest manufacturer of vehicle heating systems;[4]
See also
- Gas heater
- Kerosene heater
References
- ^ a b Purificador de aire Olansi (jpg), 1972, retrieved March 1, 2009
- ^ Lamm, Michael (1995), South Wind, AmericanHeritage.com, archived from the original on October 20, 2007, retrieved March 1, 2009
- ^ Kelly Aerospace heaters, kellyaerospace.com, archived from the original on July 30, 2007, retrieved March 1, 2009
- ^ How an Espar Airtronic air heater works, espar.com, archived from the original on August 21, 2007, retrieved March 1, 2009
- v
- t
- e
concepts
- Air changes per hour
- Bake-out
- Building envelope
- Convection
- Dilution
- Domestic energy consumption
- Enthalpy
- Fluid dynamics
- Gas compressor
- Heat pump and refrigeration cycle
- Heat transfer
- Humidity
- Infiltration
- Latent heat
- Noise control
- Outgassing
- Particulates
- Psychrometrics
- Sensible heat
- Stack effect
- Thermal comfort
- Thermal destratification
- Thermal mass
- Thermodynamics
- Vapour pressure of water
- Absorption-compression heat pump
- Absorption refrigerator
- Air barrier
- Air conditioning
- Antifreeze
- Automobile air conditioning
- Autonomous building
- Building insulation materials
- Central heating
- Central solar heating
- Chilled beam
- Chilled water
- Constant air volume (CAV)
- Coolant
- Cross ventilation
- Dedicated outdoor air system (DOAS)
- Deep water source cooling
- Demand controlled ventilation (DCV)
- Displacement ventilation
- District cooling
- District heating
- Electric heating
- Energy recovery ventilation (ERV)
- Firestop
- Forced-air
- Forced-air gas
- Free cooling
- Heat recovery ventilation (HRV)
- Hybrid heat
- Hydronics
- Ice storage air conditioning
- Kitchen ventilation
- Mixed-mode ventilation
- Microgeneration
- Passive cooling
- Passive daytime radiative cooling
- Passive house
- Passive ventilation
- Radiant heating and cooling
- Radiant cooling
- Radiant heating
- Radon mitigation
- Refrigeration
- Renewable heat
- Room air distribution
- Solar air heat
- Solar combisystem
- Solar cooling
- Solar heating
- Thermal insulation
- Thermosiphon
- Underfloor air distribution
- Underfloor heating
- Vapor barrier
- Vapor-compression refrigeration (VCRS)
- Variable air volume (VAV)
- Variable refrigerant flow (VRF)
- Ventilation
- Water heat recycling
- Air conditioner inverter
- Air door
- Air filter
- Air handler
- Air ionizer
- Air-mixing plenum
- Air purifier
- Air source heat pump
- Attic fan
- Automatic balancing valve
- Back boiler
- Barrier pipe
- Blast damper
- Boiler
- Centrifugal fan
- Ceramic heater
- Chiller
- Condensate pump
- Condenser
- Condensing boiler
- Convection heater
- Compressor
- Cooling tower
- Damper
- Dehumidifier
- Duct
- Economizer
- Electrostatic precipitator
- Evaporative cooler
- Evaporator
- Exhaust hood
- Expansion tank
- Fan
- Fan coil unit
- Fan filter unit
- Fan heater
- Fire damper
- Fireplace
- Fireplace insert
- Freeze stat
- Flue
- Freon
- Fume hood
- Furnace
- Gas compressor
- Gas heater
- Gasoline heater
- Grease duct
- Grille
- Ground-coupled heat exchanger
- Ground source heat pump
- Heat exchanger
- Heat pipe
- Heat pump
- Heating film
- Heating system
- HEPA
- High efficiency glandless circulating pump
- High-pressure cut-off switch
- Humidifier
- Infrared heater
- Inverter compressor
- Kerosene heater
- Louver
- Mechanical room
- Oil heater
- Packaged terminal air conditioner
- Plenum space
- Pressurisation ductwork
- Process duct work
- Radiator
- Radiator reflector
- Recuperator
- Refrigerant
- Register
- Reversing valve
- Run-around coil
- Sail switch
- Scroll compressor
- Solar chimney
- Solar-assisted heat pump
- Space heater
- Smoke canopy
- Smoke damper
- Smoke exhaust ductwork
- Thermal expansion valve
- Thermal wheel
- Thermostatic radiator valve
- Trickle vent
- Trombe wall
- TurboSwing
- Turning vanes
- Ultra-low particulate air (ULPA)
- Whole-house fan
- Windcatcher
- Wood-burning stove
- Zone valve
and control
- Air flow meter
- Aquastat
- BACnet
- Blower door
- Building automation
- Carbon dioxide sensor
- Clean air delivery rate (CADR)
- Control valve
- Gas detector
- Home energy monitor
- Humidistat
- HVAC control system
- Infrared thermometer
- Intelligent buildings
- LonWorks
- Minimum efficiency reporting value (MERV)
- Normal temperature and pressure (NTP)
- OpenTherm
- Programmable communicating thermostat
- Programmable thermostat
- Psychrometrics
- Room temperature
- Smart thermostat
- Standard temperature and pressure (STP)
- Thermographic camera
- Thermostat
- Thermostatic radiator valve
trades,
and services
- Architectural acoustics
- Architectural engineering
- Architectural technologist
- Building services engineering
- Building information modeling (BIM)
- Deep energy retrofit
- Duct cleaning
- Duct leakage testing
- Environmental engineering
- Hydronic balancing
- Kitchen exhaust cleaning
- Mechanical engineering
- Mechanical, electrical, and plumbing
- Mold growth, assessment, and remediation
- Refrigerant reclamation
- Testing, adjusting, balancing
organizations
- Indoor air quality (IAQ)
- Passive smoking
- Sick building syndrome (SBS)
- Volatile organic compound (VOC)
- ASHRAE Handbook
- Building science
- Fireproofing
- Glossary of HVAC terms
- Warm Spaces
- World Refrigeration Day
- Template:Home automation
- Template:Solar energy